拉力试验机力值不显示可能原因
添加时间:2019/10/23 16:22:14     浏览次数:
拉力试验机力值不显示可能原因
Possible reasons for the force value of tensile testing machine not showing
拉力机力值不显示有拉力机,拉力试验机的传感器本身故障
The force value of the tensile machine does not show that there is a failure of the sensor of the tensile machine.
拉力试验机力值不显示的拉力机主板和线路故障,处理方法检查拉力机传感器的联接线接触是否良好,可以对传感器的接头重新插拔一下如果没有解决有可能是拉力机主板已损坏。需要与厂家杭州金迈仪器仪器。
For the main board and line fault of the tensile machine whose force value does not display, the handling method is to check whether the connection line of the sensor of the tensile machine is in good contact. The connector of the sensor can be plugged and unplugged again. If it is not solved, the main board of the tensile machine may be damaged. Need to work with manufacturer Hangzhou Jinmai instruments.
拉力机传器感是否损坏,损坏原因有,传感自然老化寿命已到。人为损坏使传感器过载或不小心在测试中传感器与下夹具撞击到了一块。处理方法需要更换杭州金迈仪器仪器的拉力机传感器。
Whether the sensor of the tension machine is damaged? The reasons for the damage are as follows: the natural aging life of the sensor has reached. The sensor is overloaded due to man-made damage or accidentally collided with the lower clamp during the test. The treatment method needs to replace the tension machine sensor of Hangzhou Jinmai instrument.